Search results for " Perfusion"
showing 10 items of 137 documents
Iron-loaded transferrin (Tf) is detrimental whereas iron-free Tf confers protection against brain ischemia by modifying blood Tf saturation and subse…
2018
Despite transferrin being the main circulating carrier of iron in body fluids, and iron overload conditions being known to worsen stroke outcome through reactive oxygen species (ROS)-induced damage, the contribution of blood transferrin saturation (TSAT) to stroke brain damage is unknown. The objective of this study was to obtain evidence on whether TSAT determines the impact of experimental ischemic stroke on brain damage and whether iron-free transferrin (apotransferrin, ATf)-induced reduction of TSAT is neuroprotective. We found that experimental ischemic stroke promoted an early extravasation of circulating iron-loaded transferrin (holotransferrin, HTf) to the ischemic brain parenchyma.…
2019
The cytokine interleukin-1 (IL-1) is a key contributor to neuroinflammation and brain injury, yet mechanisms by which IL-1 triggers neuronal injury remain unknown. Here we induced conditional deletion of IL-1R1 in brain endothelial cells, neurons and blood cells to assess site-specific IL-1 actions in a model of cerebral ischaemia in mice. Tamoxifen treatment of IL-1R1 floxed (fl/fl) mice crossed with mice expressing tamoxifen-inducible Cre-recombinase under the Slco1c1 promoter resulted in brain endothelium-specific deletion of IL-1R1 and a significant decrease in infarct size (29%), blood-brain barrier (BBB) breakdown (53%) and neurological deficit (40%) compared to vehicle-treated or con…
Conditioned Medium from Human Amnion-Derived Mesenchymal Stromal/Stem Cells Attenuating the Effects of Cold Ischemia-Reperfusion Injury in an In Vitr…
2021
The clinical results of lung transplantation (LTx) are still less favorable than other solid organ transplants in both the early and long term. The fragility of the lungs limits the procurement rate and can favor the occurrence of ischemia-reperfusion injury (IRI). Ex vivo lung perfusion (EVLP) with Steen SolutionTM (SS) aims to address problems, and the implementation of EVLP to alleviate the activation of IRI-mediated processes has been achieved using mesenchymal stromal/stem cell (MSC)-based treatments. In this study, we investigated the paracrine effects of human amnion-derived MSCs (hAMSCs) in an in vitro model of lung IRI that includes cold ischemia and normothermic EVLP. We found tha…
Development of a novel in vitro system for biomedical applications
2022
Nella ricerca scientifica e medica, l'uso degli animali ha apportato notevoli benefici all’uomo. Sebbene la loro fisiologia non imiti perfettamente il corpo umano, essi agiscono come perfetti "modelli" per lo studio delle malattie umane e lo sviluppo di nuovi farmaci e trattamenti. Tuttavia, secondo la Food and Drug Administration (FDA), solo l'8% dei farmaci testati sugli animali è considerato sicuro ed efficace per l'uso sull’essere umano, il 92% non lo è. Questi tassi di fallimento estremamente elevati nello sviluppo di farmaci, insieme ai costi in forte aumento, hanno portato molti ricercatori a rivalutare il valore degli studi in vivo sugli animali. Questo è stato il motivo per cui, ne…
Cubic Microcontainers Improve In Situ Colonic Mucoadhesion and Absorption of Amoxicillin in Rats
2020
An increased interest in colonic drug delivery has led to a higher focus on the design of delivery devices targeting this part of the gastrointestinal tract. Microcontainers have previously facilitated an increase in oral bioavailability of drugs. The surface texture and shape of microcontainers have proven to influence the mucoadhesion ex vivo. In the present work, these findings were further investigated using an in situ closed-loop perfusion technique in the rat colon, which allowed for simultaneous evaluation of mucoadhesion of the microcontainers as well as drug absorption. Cylindrical, triangular and cubic microcontainers, with the same exterior surface area, were evaluated based on i…
Brain tissue pO2 related to SjvO2, ICP, and CPP in severe brain injury
2000
The aim of this report is to present first experience in comparing the course of brain tissue oxygen pressure values (PtiO2) to changes in jugular vein oxygen saturation (SjvO2), intracranial pressure (ICP), and cerebral perfusion pressure (CPP) after severe brain injury. PtiO2 monitoring was done using a polarographic Clark type microcatheter (LICOX pO2 probe) (GMS, Kiel, Germany) with a diameter of 0.5 mm and a sensitive area 7.9 mm long inserted in a right frontal position. The microcatheter was connected to a LICOX pO2 device. A fiber-optic catheter was used to measure SjvO2 and placed into the right internal jugular vein. The ICP monitoring was performed with a fiber-optic intraparench…
Realignment of myocardial first-pass MR perfusion images using an automatic detection of the heart-lung interface
2004
International audience; Abstract: Magnetic resonance first-pass imaging of a bolus of contrast agent is well adapted to distinguish normal and hypoperfused areas of the myocardium. In most cases, the signal intensity-time curves in user defined regions of interest (ROI) are studied. As image acquisition is ECG-gated, the images are acquired at the same moment in the cardiac cycle, and the basic shape of the heart is similar from one view to the next. However, superficial respiratory motion can displace the heart in the short-axis plane. The aim of this study is to correct for the respiratory motion of the heart by performing an automatic realignment of the myocardial ROI based on a method t…
Dynamic contrast-enhanced myocardial perfusion imaging using saturation-prepared TrueFISP.
2002
Purpose To develop and test a saturation-recovery TrueFISP (SR-TrueFISP) pulse sequence for first-pass myocardial perfusion imaging. Materials and Methods First-pass magnetic resonance imaging (MRI) of Gd-DTPA (2 mL) kinetics in the heart was performed using an SR-TrueFISP pulse sequence (TR/TE/α = 2.6 msec/1.4 msec/55°) with saturation preparation TD = 30 msec before the TrueFISP readout. Measurements were also performed with a conventional saturation-recovery TurboFLASH (SRTF) pulse sequence for comparison. Results SR-TrueFISP images were of excellent quality and demonstrated contrast agent wash-in more clearly than SRTF images. The signal increase in myocardium was higher in SR-TrueFISP …
High-frequency oscillatory ventilation in adults with traumatic brain injury and acute respiratory distress syndrome
2005
This study observed adverse events of rescue treatment with high-frequency oscillatory ventilation (HFOV) in head-injured patients with acute respiratory distress syndrome (ARDS).Data of five male patients with ARDS and traumatic brain injury, median age 28 years, who failed to respond to conventional pressure-controlled ventilation (PCV) were analyzed retrospectively during HFOV. Adjusted mean airway pressure at initiation of HFOV was set to 5 cm H2O above the last measured mean airway pressure during PCV. Frequency of pulmonary air leak, mucus obstruction, tracheal injury, and need of HFOV termination due to increased intracranial pressure, decreased cerebral perfusion pressure, or deteri…
Correlation of cerebral blood flow and MCA flow velocity measured in healthy volunteers during acetazolamide and CO2 stimulation
1995
Abstract The assessment of the cerebrovascular reserve capacity (RC) has become a widely used tool in the management of cerebrovascular disease. Discrepancies become obvious, however, if results obtained with different methods are compared. Aim of the present study, therefore, was to compare blood velocity and cerebral perfusion data in the same group of healthy test persons. In 32 volunteers regional cerebral blood flow (rCBF) was measured with the 133 Xe-inhalation method. F1 as grey matter flow and the initial slope index (ISI) were computed. Simultaneously flow velocity in the middle cerebral artery (V MCA ) was assessed by transcranial Doppler sonography (TCD). Measurements were perfor…